Every clinic, hospital, aged care home and dental practice relies on equipment that touches patients or keeps them safe. Medical equipment testing is how you prove that equipment is electrically safe, working to specification and ready for an accreditation audit. This guide explains what testing covers, how it differs from ordinary test and tag, how often it is needed and what you should get back at the end.
What is medical equipment testing?
Medical equipment testing is the routine inspection, electrical safety testing and performance checking of medical electrical equipment. In Australia and New Zealand it is carried out to AS/NZS 3551, the standard for managing medical equipment across its whole life, from acceptance testing when it arrives to scheduled checks and repairs until it is retired.
A typical test covers three things:
- Visual inspection. Cases, cables, plugs, patient leads, labels and accessories are checked for damage or wear.
- Electrical safety testing. Earth continuity, insulation and leakage currents are measured, including leakage through applied parts that connect to the patient. See our electrical safety testing service.
- Performance checks. The device is checked against the manufacturer’s specification, for example the energy delivered by a defibrillator, the accuracy of a blood pressure monitor or the readings from a patient monitor.
Is it the same as test and tag?
No. General test and tag under AS/NZS 3760 is designed for everyday electrical items such as kettles, computers and extension leads. It does not measure patient leakage currents or check that a device is doing its clinical job. Medical electrical equipment needs testing to AS/NZS 3551 by people trained in biomedical equipment. Our post on AS/NZS 3551 vs AS/NZS 3760 explains the difference in detail.
Who needs medical equipment testing?
- Hospitals working to the NSQHS Standards.
- GP and specialist practices preparing for RACGP accreditation through AGPAL or QIP.
- Aged care homes meeting the Aged Care Quality Standards.
- Dental practices, day surgeries, allied health clinics and pathology collection centres.
- Ambulance services, mine site medical rooms, schools and workplaces with AEDs or first aid equipment.
How often should medical equipment be tested?
Most facilities test medical electrical equipment at least once a year, with higher risk equipment or equipment in heavy use checked more often. The right interval depends on the device type, the manufacturer’s recommendations and your own risk assessment. New equipment should also be acceptance tested before it is used on a patient, and equipment should be tested again after any repair. Our guide to AS/NZS 3551 testing frequency goes into this further.
What you should get back
Testing is only as useful as the records it leaves behind. At the end of a visit you should have:
- A test tag or label on each item showing when it was tested and when it is next due.
- A full equipment register listing every device, its location and its result.
- Clear notes on anything that failed, with a repair or replacement recommendation.
- Reports in a format your accreditation assessor or compliance platform can accept.
On site testing with Nova Biomedical
Nova Biomedical tests medical equipment on site for hospitals, clinics, aged care and dental practices across Queensland, New South Wales, Western Australia and New Zealand. We are ISO 9001:2015 certified, test multiple brands in one visit and can repair most faults we find. For ongoing peace of mind, a planned preventive maintenance contract keeps every device on schedule.
Call 1300 723 900 or request a quote.
Frequently asked questions
Can an electrician test medical equipment?
An electrician can test general electrical items to AS/NZS 3760, but medical electrical equipment should be tested to AS/NZS 3551 by a biomedical engineer or technician with the right test equipment, such as an electrical safety analyser that measures patient leakage.
Do you need to close the clinic during testing?
Usually not. Testing is worked around your patient lists, room by room, so most practices keep seeing patients while we test.
What happens if a device fails?
It is tagged out of service and recorded on your report with the reason. We will tell you whether it can be repaired on site, needs parts or should be replaced.